Resources:
Datasheet:
www.dialight.com/Assets/Brochures_And_Catalogs/Illumination/MDEXSSWPCHZC001.pdf•
Case Studies, IES Files, LM79 Reports:
www.dialight.com/Document/Index/709SafeSite
®
LED Bulkhead Fixture
Dimensions
Ratings and Certifications
•
L70 >100,000 hours @ 25°C ambient
•
ATEX/ IECEx Zones 1 & 21
•
ATEX/ IECEx Zones 2 & 22
•
CE
•
IP66/67
•
IK09
•
Additional LED colours available:
Green - for emergency shower lighting
Red - for emergency lighting
•
5yr full performance warranty
Comparison
Warranty L-70 T-Rating
Dialight
Bulkhead
5yr
>100,000 T6
Metal Halide
1
15,000
T2
High Pressure
Sodium
1
20,000 T2A
Light Distribution
Wide Optic
Oval Optic (35 x55)
Oval Optic 55x35
Dimensions in mm (inches)
SafeSite
Specifications
Fixture Weight:
Power Factor:
>0.9
Standard & Amber Models
THD:
<15% @ 120V AC
11W / 22W /34W: 5.40kg
<20% @ 230V AC
Emergency & Amber Emergency Models
Surge Protection:
1 kV line to line
2 kV line to ground
13W / 24W / 36W: 5.40kg
Voltage Range:
Housing:
Copper free aluminium
Standard & Amber Models
Lens Options:
High impact resistant glass
11W & 22W:
100 - 277V AC or 24 - 48V DC
Clear glass or frosted glass
34W:
100 - 277V AC
CRI:
70
Emergency & Amber Emergency Models
CCT:
5,650K (cool white)
13W & 24W:
90 - 132V AC or 207 - 264V AC
4,300K (neutral white)
36W:
207 - 264V AC
Emergency Models
Operating Temp:
Battery
Standard & Amber models
13W & 24W:
3.6V 4Ah NiMH
11W & 22W:
-40°C to +60°C
36W:
3.6V 10Ah NiMH
34W:
-40°C to +50°C
Expected Battery Life:
4 years
Emergency & Amber Emergency Models
(-20°C options available)
Battery Duration:
>180 Minutes @ lowest
13W & 24W:
0°C to +50°C
rated temperature
36W:
0°C to +40°C
Mounting Options
:
Refer to page 32
Standard Model
Lumens
Wattage lm/W Mounting Heights
2,250
34
66
6m
2,150
34
63
1,200
22
55
600
11
55
3m
Emergency Model
Lumens
Wattage lm/W Mounting Heights
2,250
36
63
6m
2,150
36
60
1,200
24
50
600
13
46
3m
30
www.
led4industry.cz